Your contractor
Design, supply and installation (EPC)
One contract and one party answerable from site survey to handover. What makes us different is how we deliver it.
Why Arohan
-
We check our own work the way an owner's engineer would
Arohan also works as the client's engineer, and we hold our EPC projects to the same checks: we survey before we price, you sign a specification before anything is bought, the system is accepted only on tests your team witnesses, and you receive complete handover documents.
-
Monitoring after handover, built by our own software team
A system can come with monitoring built by Prakreon, our software team: continuous earthing health monitoring, and CCTV detection of unsafe acts and conditions. Where you choose it, you see how the system is doing after we leave, not only on the day it was handed over.
-
Led by an engineer who has built infrastructure
Arohan's founder, Viral Patel, built and commissioned 247 km of steel and 900 km of PE gas network at Gujarat Gas, and delivered 16 CNG stations among other works at Adani Total Gas. That record is his, not the firm's: Arohan was registered in July 2026, and we say so.
-
Safety designed in from the first drawing
Fire and electrical safety are part of the design, not an add-on at the end: battery fire and thermal-runaway safeguards, earthing and lightning protection, and fire and life-safety systems are specified with the system and tested before handover.
What we build
- Solar, rooftop and ground-mount
- Battery storage
- Earthing and lightning protection
- Fire and life-safety systems
- CCTV safety monitoring
- Mechanical car parking, G+1 to G+3
- Other site infrastructure
Examples, not a closed list. If your site needs something else built, ask.
Scope
- Site survey and design
- Procurement from qualified equipment makers
- Installation, with electrical work by licensed installers
- Testing and commissioning witnessed by your team
- Handover documents and operator training
- Annual maintenance, and monitoring where fitted
One contract, one site lead and one party answerable when something does not work: that is EPC. The cards above are why owners choose us to do it.
Mechanical car parking
A stack system lifts parked cars on platforms so that two to four cars use the floor space of one. It needs a minimum clear height, a level slab or a pit depending on the model, and a reliable power supply. Safety interlocks, sensors and locking devices are part of the specification, not options. We survey the site, recommend the system that fits it, supply it from a qualified maker, install and commission it, and maintain it under an annual contract.
One role on each project
As your contractor we are not also your independent engineer on the same project, and we say so at the top of the proposal. On other projects, where someone else is the contractor, we can be the engineer on your side.
How an EPC project runs
- 01
Site survey
A survey record and the site constraints that decide what can be built and what it costs.
- 02
Design & specification
A specification and price you sign before anything is bought.
- 03
Procurement
Equipment with its makers' certificates, test records and warranties.
- 04
Installation
An installed system with inspection records and every non-conformance closed.
- 05
Testing & commissioning
A commissioning record you sign, on test results rather than on a date.
- 06
Handover
A handover pack your team can run the system from.
- 07
Maintenance & monitoring
The system kept to its specification, with readings you can see between visits where monitoring is fitted.
What you actually receive
Services describe activity. These are the artefacts that exist at the end, and that you own.
-
Survey and design
A survey record, layout and general-arrangement drawings, single-line diagrams, and the civil works and clearances the system needs, agreed with you before procurement.
-
Specification you sign
The equipment, the performance, the tests and the acceptance criteria, signed before anything is bought, and the document the system is checked against at handover.
-
Equipment with its records
Make, model and specification of every major item, with the maker's test certificates, factory acceptance records where they apply, and warranty terms.
-
Commissioning record
Test results against the specification, witnessed and signed by your team.
-
Handover pack
As-built drawings, operation and maintenance manual, safety instructions, spares list, warranty documents and operator training.
-
Maintenance and monitoring
An annual maintenance contract with planned visits, response times and annual tests, and monitoring readings where monitoring is fitted.
How we hold ourselves to it
- One role per project, declared in writing. As your contractor we are not also your independent engineer on that project.
- Equipment comes from qualified makers, with their test certificates and warranties carried through to you.
- Electrical installation is carried out by licensed electrical contractors working under Arohan's responsibility.
- Nothing is described as delivered on this site until it has been installed, commissioned and handed over.
Questions buyers ask about this work
Do you build the system yourselves?
Yes. As your EPC contractor we design, supply, install and commission it under one contract, with our own team leading the site and licensed installers doing the electrical work.
Do you only build the systems listed here?
No. They are examples. Tell us what your site needs; if it is energy or site infrastructure we can design, procure and install with qualified makers and licensed installers, we will quote for it, and if not we will say so.
Do you manufacture the equipment?
No. We design the system, select and buy equipment from qualified makers against the signed specification, and install and commission it. The maker's warranty is carried through to you.
Who does the electrical work?
Licensed electrical contractors, working under Arohan's responsibility on the project. Their licence details are given in the proposal.
Can you also be our independent engineer on the same project?
No. On any one project we hold one role. If you want our work checked independently, appoint another firm and we will work with them. We can be your engineer on a project where someone else is the contractor.
What do you need to quote mechanical car parking?
The number of cars, the system type you have in mind (stack or puzzle, G+1 to G+3), the available clear height and plan area, whether a pit is possible, and the power supply at the location. A site visit confirms the rest.
Is monitoring included?
It is an option, priced separately. Where you choose it, earthing health monitoring or CCTV safety monitoring is designed with the system and handed over with it.